Fire mobile lighting device YZ2-2.2F

Products

Name

Fire mobile lighting device YZ2-2.2F

I want to make an inquiry
Parameters
Performance
Instructions
Precautions
The video
Corresponding parameter set not found, please add it in property template of background

1, lighting fixtures
 
Working voltage:220 

V Lamp power W:4*500

Average service life h:2000

2, lifting rod
 
Material:Aluminum alloy

Maximum Height:3.5m

Minimum Height:1.3m

Rise Time:16.8s

Fall Time:21.3s
 

3, generator
 
Rated output voltage V, power KW:       220V,≥2KW
Continuous work performance:           Once full of fuel can work 13 hours
Size:                                600*480*440mm
Start method:                         Hand start
Type:                               Four-stroke air-cooled
Operating noise dB:                   86.5
         

YZ2-2.2F fire-fighting mobile lighting device is suitable for mobile lighting of various large-scale construction

operations, engineering repairs, disaster rescue, fire lighting, police scene, accident handling and other scenes.

1. Push the product into the workplace and place it steadily, and press down the two universal wheel locks to lock

the wheels to ensure that they do not roll;

2. Place the lifting cylinder vertically and tighten the manual screw;

3. Place the lamp panel on the shaft of the lifting cylinder, tighten the screws after adjusting the orientation, and

then connect and tighten the aviation plug with the aviation socket of the lamp panel, and then insert the power plug

on the cylinder into the socket on the generator;

4, check the generator load switch, should be placed in the OFF position;

5, check the engine oil level: (see engine specification)

(1) Open the oil cap and clean the oil feeler with a clean cloth.

(2) Insert the oil feeler gauge into the fuel filler port. At this time, it is not necessary to rotate the oil feeler

gauge. If the oil level is lower than the lower limit of the oil feeler gauge, add the oil.

(3) Fill the oil limit to the oil level gauge.

(4) Firmly install the oil feeler gauge.

6, check the air filter to ensure clean and in good condition;

7. Before starting the engine, connect the generator power cable to the manual control box;

8, the air pump power received manual control box;

9, the handle control box diameter 8mm air pipe connected to the air rod, diameter 6mm connected to the air pump;

then connect the lamp switch power supply;

10. Put the fuel valve in the ON position. When the cold starts, place the choke lever to the “CLOSE” position

(do not pull the choke lever to the “CLOSE” position when starting), gently pull Zhi Qi

Handle it until it feels resistance, then pull it hard. After the start, do not allow the handle to spring back.

Gently put it back. When the engine warms up, pull the damper door back.

11. When using manual work, please turn on the main switch power supply of the manual control box first, and the

lamp post will rise to the maximum and keep it closed after 5-10 seconds (built-in 0.2MPa pressure switch);

12. When using the remote controller, please turn off the main switch power supply of the manual control box first.

A total of four remote control switch: A control air lift, B control air drop, C control light group one, D control

light group two;

13. After the work is completed, the remote air is deflated. You can also use the manual control box to manually

deflate the air (you need to control the main power to open the air before deflation). You can also press and hold

the manual air release valve to lower the lamp post. After the lamp cools down

Separately remove the aviation plug, loosen the lock nut, remove the lamp pan, and load it into the iron box.

1. The exhaust of the engine is toxic. Do not use it in a closed place.

2. When refueling, be sure to turn off the engine.

3. Do not smoke while refueling or refuel near a flame.

4. Be careful not to spill fuel and spill on the engine while refueling.

5, can not be used in direct rain environment.

6. Do not disassemble the lamp during the work process, otherwise it may cause electric shock. When disassembling,

make sure that all power is turned off.

7. When the lamp is working, it is very hot. Please make sure there are no flammable or explosive materials around

the system. Do not put your hands on the lamp to prevent burns.

8. When the lamp tube is replaced, the lamp housing should be opened after it is naturally cooled, and the lamp tube

should be replaced with a glove to prevent the fingerprint of the lamp tube from affecting the service life of the

lamp tube.

9. When the lifting cylinder is extended or retracted, do not place the hand or object on the retractable point to

prevent crushing.

10. When the lamps and lanterns work for a long time, it is a normal phenomenon that the lifting cylinders are

slightly reduced. The lamp posts should be pressurized in time.

11, in the high-voltage electrical wires and other environmental work, after the lamp plate rises and the high-

voltage line distance of at least more than 5 meters, in thunderstorm days, open places should be used reliably

grounded to prevent lightning.

12.When the lamp fails, it should be checked by a professional or trained personnel. Please do not disassemble it

to prevent injury.