Jiujiang fire fighting equipment Co., Ltd 

>
>
>
Fire extension ladder TEL6

Products

Name

Fire extension ladder TEL6

I want to make an inquiry
Parameters
Performance
Instructions
Precautions
The video
Corresponding parameter set not found, please add it in property template of background

Model no.

Extension lengthm

Step distance mm

Maximum widthmm

Weight kg

TEL6

6±0.2

300±2

300±3

28±2.5

TEL9

9±0.2

300±2

300±3

52±4.5

Remarks: 6m, 9m ladder without wheels, without poles.

 

Fire ladder TEL6 is made of high-strength aluminum alloy material. It is mainly used in small and medium-sized cities

without high-lift cars and ordinary ladders. It is an indispensable tool for firefighters to climb to save people and

put out fires. It is also suitable for factories, institutions, military units, shops, electricians, installers, and

municipal construction personnel to climb the work. It is widely used.

1. According to actual needs, determine the working height required for the ladder, and then determine the position

of the ladder on the ground. The distance from the wall to the wall is about 1/4 of the working height of the ladder.

The ladder is inclined in the direction of the wall, and the angle with the ground is about 75°.

2. Pull down the nylon drawstring. At this time, the upper ladder rises. When the height is reached, loosen the

nylon rope upwards (note that the hand does not leave the drawstring at this time). At this time, the support foot

will automatically support the next section.

On the ladder, tie the rope to any ladder on the lower section to increase the safety factor of the ladder, and the

hand can leave the drawstring. Then lift the two support rods on the ground to make appropriate adjustments, and then

return to the ground.

The entire ladder can be placed against the wall. The ladder personnel stand on the side of the wall to protect the

feet and can climb at this time.

3. When the work is completed and needs to be lowered, pull down the nylon rope to raise the ladder by about 15 cm,

so that the legs leave the ladder, and then slowly relax the nylon rope upwards, and the ladder will drop and

condense. Not at this time

Suddenly let go of the rope and avoid the ladder falling freely and being damaged. The correct way is to alternately

loosen the rope with both hands and lower the ladder.

1. The maximum number of people using the ladder is two.

2. The safe use angle of the ladder is 70°~76°, and the best use angle is 75°.

3. The support rods on both sides of the ladder should be used at the same time and the support angle is the same.

4. After the ladder is raised against the wall, the ladder rope should be tightened and tied on the ladder to be

able to climb the ladder.

5. The ladder person should stand between the ladder and the wall, and use both hands to hold the outer edge of the

side panels on both sides. When the work is completed, the ladder personnel must leave the ladder to prevent the

ladder from colliding when the ladder is lowered.

ACCIDENT.

6. It is strictly forbidden to hang up the ladder to work on the ladder.

7. It is strictly forbidden to pass the bridge after the launch.

8. In the fire fighting battle, try to lean the ladder on the outer wall or firewall of the building. When using the

fire ladder near the open fire area, apply water gun cooling protection.

9. Fire-fighting rescue ladders and training ladders should be stored separately and markedly marked.