简体中文

Welcome to Jiujiang fire fighting equipment Co., Ltd 

ENGLISH

jjxf@jjxf.com.cn

400-0792-119

Follow us

ADD:No.1,Daqiao Road,Yujiahe,Lianxi District,Jiujiang City,Jiangxi province,China
TEL:400-0792-119
FAX:0792-8578766
E-MAIL:
jjxf@jjxf.com.cn

CONTACT US

Jiujiang fire fighting equipment Co., Ltd  © CopyRights

Jiujiang fire fighting equipment Co., Ltd 

>
>
>
>
hydraulic motor-driven pump BJQ63/0.6-S/B

Products

Name

hydraulic motor-driven pump BJQ63/0.6-S/B

I want to make an inquiry
Parameters
Performance
Instructions
Precautions
The video
Corresponding parameter set not found, please add it in property template of background

Item

parameters

Model no. of engine

Honda GXH100 gasoline engine

Rated high pressure MPa

≥63

Rated high pressure flow rate L/min

0.62

Low pressure output pressure MPa

10

Low pressure output flow L/min

1.93

Weight (including hydraulic oil, engine oil, gasoline)

≤31kg

Recommended fuel

90#-93# unleaded gasoline

 

Recommended hydraulic oil

Anti-wear type YB-N3

 

Connector Type

Double Tube Single Connector

 

1. This motorized pump can simultaneously work for two demolition tools without affecting each other.

2. Large flow and fast speed, suitable for more complex rescue places.

3, low noise, low energy consumption, light weight, easy to carry.

4, each high and low voltage automatic conversion, so that performance is safe and effective.

5, bracket type tooling, more convenient for rescue workers to carry.

6, with 2 sets of 5m hydraulic pipe assembly or optional 10m hydraulic pipe assembly spare.

First, the engine is topped up with gasoline and oil, and the hydraulic tank is also filled with hydraulic oil.

Connect the soft tubing to the rescue tool.

1. Open the fuel tank and turn the fuel tank switch counterclockwise to the ON position. At this point, the gasoline

flows to the carburetor.

2, close or close the small choke, turn counterclockwise to off, clockwise to open (note: when the engine is hot or

hot weather, do not need to close the damper).

3. Refer to the engine manual, adjust the throttle handle, and adjust the speed for each work.

4. Turn the circuit switch on the engine clockwise from OFF to the ON position to turn the ignition circuit on.

5. Finally, turn the hydraulic oil pump manual switch to the counterclockwise direction to the OFF position (empty

load).

6. After the above is ready, you can start the gasoline engine. After the running speed is stable, finish

When the choke is fully opened, when the machine needs to work, turn the oil output switch clockwise to the ON

working position with a slight force, and the rescue tool can operate normally.

7. When operating the A oil circuit switch: the A road breaking tool can work; when the B oil circuit switch is

operated, the B oil circuit breaking tool works (right rotation is working, left rotation is stopping). Simultaneous

operation, no interference with each other.

1. The hydraulic motorized pump should be placed or operated in a horizontal position as much as possible.

2. Read the instruction manual of the small gasoline engine carefully before using, adjusting and maintaining the

engine. Check the three oil levels before starting:

1) The engine reducer is a four-stroke gasoline engine, model: QF or QG grade 15W-40 viscosity grade.

2) Anti-wear properties of working hydraulic oil, generally choose YB-N32 with moderate viscosity. When the ambient

temperature is ≥-2°C, YB-N22 can be used. Do not add slop oil. Fuel tank gasoline position: Add unleaded gasoline

above 90# as required, and do not add too much to prevent spillage.

3. The valves in the hydraulic motorized pump have been debugged before leaving the factory and should not be

adjusted at will.

4. The hydraulic motorized pump is equipped with a double pipe single joint to support pressure operation.

5. In the training or rescue work, when the supporting tools stop working, the oil circuit switch should be unloaded

in time, and the small carburetor throttle should be closed to make it idle or stop. Try to avoid long-term full-load

operation of the motorized pump to prevent the oil temperature from being too high and affect the service life.

6. Regularly check and replace or supplement the hydraulic oil and engine reducer lubricating oil (motor oil)

according to the use.

暂未实现,敬请期待
暂未实现,敬请期待
Previous article
Next article